dc.description.abstract |
Os recentes avanços tecnológicos em sensores portáteis para as
determinações das características do solo em escala de campo e em tempo
real, têm atraído a atenção da pesquisa, na busca pela implementação bem-
sucedida da agricultura de precisão. Um exemplo disso são os equipamentos
móveis para medição da matéria orgânica (MO), que são utilizados no campo
para fins agrícolas e sustentáveis. Dessa forma, considerando que a utilização
de equipamentos para a medida de parâmetros físico-químicos do solo in situ
ainda é recente no Brasil, o presente trabalho possui como objetivo avaliar a
exatidão dos resultados obtidos com o uso dos sensores ópticos VisNIR, para a
determinação da MO do solo. O trabalho foi realizado sobre uma gleba
pertencente à área do Instituto Federal de Ciência e Tecnologia do Rio Grande
do Sul (IFRS), Campus Ibirubá, onde foram realizados os manejos previstos,
coleta das amostras de solo, avaliações e calibração do equipamento e,
avaliações de matéria orgânica a campo utilizando os sensores dinâmicos. O
solo da área é classificado como Latossolo Vermelho. No Laboratório de Solos
e Tecido Vegetal da instituição foram realizadas as avaliações da MO, por meio
da metodologia padrão de laboratório (colorimetria), que utiliza solução
sulfocrômica (Na2Cr2O7 15% em H2SO4 5,0 mol L-1
), com calor externo e
determinação espectrofotométrica do Cr+3. Embora seja de fácil execução e
baixo custo, gera um alto volume de resíduos tóxicos. Para fins de
comparação, foi utilizado outro método com sensores do equipamento Veris®,
avaliado em bancada e a campo. Esse possui como princípio de medida a
emissão de um feixe de luz na amostra por meio de uma lâmpada halógena e
no recebimento da reflectância dessa energia por um sensor de fibra óptica.
Fornecendo, assim, valores de vermelho (Red) e infravermelho (IR). Ademais,
foi necessário a realização do tratamento e conversão dos dados obtidos por
ambos os métodos. Conforme EDITAL IFRS No 06/2022 - FLUXO
CONTÍNUO_PROPOSTAS QUE VISAM À GERAÇÃO DE NOVAS
TECNOLOGIAS E À PROTEÇÃO DA PROPRIEDADE INTELECTUAL, este
trabalho encontra-se em confidencialidade e sigilo, referente ao convênio
IFRS/Stara. Deste modo, a metodologia foi apresentada parcialmente e os
resultados deste trabalho não podem ser divulgados. |
pt_BR |
dc.description.abstract |
Recent technological advances in portable sensors for field-scale and real-time
determinations of soil characteristics have attracted research attention in the
search for the successful implementation of precision agriculture. An example of
this is mobile equipment for measuring organic matter (OM), which is used in
the field for agricultural and sustainable purposes. Therefore, considering that
the use of equipment for the measurement of physical-chemical parameters of
the soil in situ is still recent in Brazil, the present work aims to evaluate the
accuracy of the results obtained with the use of optical sensors VisNIR, to
determine the soil OM. The work was performed on a plot belonging to the area
of the Federal Institute of Science and Technology of Rio Grande do Sul (IFRS),
Campus Ibirubá, where the planned managements were carried out, soil
sampling, evaluations and calibration of the equipment and, evaluations of
organic matter in the field using dynamic sensors. The soil in the area is
classified as Oxisol. In the institution's Soil and Plant Tissue Laboratory, OM
analyses were performed using the standard laboratory methodology
(colorimetry), which uses a sulphochromic solution (Na2Cr2O7 15% in H2SO4 5.0
mol L-1
), with external heat and spectrophotometric determination of Cr+3
.
Although it is easy to perform and low cost, it generates a high volume of toxic
waste. For comparison purposes, another method was used with sensors from
the Veris® equipment, evaluated on the bench and in the field. This has as a
measurement principle the emission of a beam of light in the sample by means
of a halogen lamp and in the reception of the reflectance of this energy by a
fiber optic sensor. Thus, providing red (Red) and infrared (IR) values.
Furthermore, it was necessary to carry out the treatment and conversion of the
data obtained by both methods. According to EDITAL IFRS No 06/2022 -
CONTINUOUS FLOW_PROPOSALS AIMING TO GENERATE NEW
TECHNOLOGIES AND PROTECT INTELLECTUAL PROPERTY, this work is in
confidentiality and secrecy, referring to the IFRS/Stara agreement. Thus, the
methodology was presented partially and the results of this work cannot be
disclosed. |
en |
dc.format.mimetype |
application/pdf |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.rights |
Open Access |
en |
dc.subject |
Sensores |
pt_BR |
dc.subject |
Espectroscopia de infravermelho |
pt_BR |
dc.title |
Espectroscopia VisNIR aplicada na avaliação da matéria orgânica do solo |
pt_BR |
dc.type |
Trabalho de conclusão de graduação |
pt_BR |
dc.degree.grantor |
Instituto Federal de Educação, Ciência e Tecnologia do Rio Grande do Sul |
pt_BR |
dc.degree.level |
Graduação |
pt_BR |
dc.degree.local |
Ibirubá, BR-RS |
pt_BR |
dc.degree.graduation |
Bacharelado em Agronomia |
pt_BR |
dc.degree.department |
Campus Ibirubá |
pt_BR |